Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1891 - 1905 of 2470 items found.

  • PD Monitoring Systems

    Power Diagnostix Systems GmbH

    Partial discharge monitoring systems can be used for permanent surveillance of insulation systems on GIS, transformers, rotating machines, motors, cables, or other high voltage equipment. These instruments are designed for long term data recording, alarm handling, event recognition, and system integration.

  • THREE PHASE PORTABLE ENERGY METER CALIBRATION EQUIPMENT

    GF302D1 - Beijing GFUVE Electronics Co.,Ltd.

    The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.

  • Conductivity Electrode

    ALS Co., Ltd

    As current-carrying and potential difference measuring electrodes, platinum was deposited on a quartz glass substrate. Voltage terminal distance can be varied by changing the connection pin. In-situ measurement of the metal transition produced in a conductive polymer insulator doping, 4 terminal electrode is used, where for insulator layer with low doping side 2 terminal method and for metal layer with high doping side 4 terminal method is used for the measurement. With this electrode, become possible to have measurement in 15 distances by combining the connection terminal.

  • Digital I/O Channels cPCI Cards

    GX3232 - Terotest Systems Ltd.

    The GX3232 is a multi-channel 16-bit, analog input and output cPCI module, supporting 32 single-ended or 16 differential input channels and four analog output channels. The inputs can be software configured for differential or single-end operation and are sequentially scanned with a maximum aggregate scan rate of 300 kS/s. Three input ranges are software-selectable: ±10 V, ±5 V or ±2.5 V. Optionally, the GX3232 is available with a high voltage input configuration and supports three ranges: ±60 V, ±30 V and ±15 V.

  • Electrical Fast Transient Pulse Group Generator

    SKS-0404IB - Shanghai Sanki Electronic Industries Co., Ltd.

    Electrical fast transient pulse group generator SKS-0404IB fully complies with the new standards of IEC61000-4-4, EN61000-4-4 and GB/T17626.4; provides pulse test voltage up to 4500V, which can meet various product standards Severity level ; pulse frequency up to 1MHz, and continuously adjustable; imported discharge switch, high precision, long life, good reproducibility; using 7-inch true color touch screen control, convenient for users to directly program and control.

  • THERMO & A/D MODULE OF THE COMPACT DEVICE FAMILY

    ES650 - ETAS GmbH

    Featuring 16 electrically insulated measuring channels for analog voltages and an adjustable acquisition rate per module, this module provides high measuring accuracy through 16-bit (A/D) or 21-bit (thermal) resolution. Signal smoothing occurs through a parameterized software filter, and offers two selectable measuring ranges of 10 V and 60 V. The automotive measuring range is -210 C to 1372 C (-346 F to 2502 F). Data transfer to PC occurs via Ethernet.

  • 3 3/4 Digits AC/DC Current Digital-Clamp Multimeter

    KT7193 - Ketai instrument (kunshan) Ltd.

    ● 3 3/4 digits 3999 count● Extra high DC/AC current measurement● Data hold to capture measurements● Backlit display is easy to read under any light condition● AC current measurement up to 1500A● DC current measurement up to 1500A● DC/AC voltage, resistance, capacitance, frequency and temperature measurement● Diode and continuity test● Accessories included: 9V battery, carrying case, test leads, K typetemperature probe, English manual, gift box

  • Current Transformer Pin Type

    PCT 1 - Shanghai Powoo Industry Develop Group Limited

    - completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - the secondary lead wire is pin format, which can be directly welded on a PCB; - the primary lead wire could be pin, soft wire as well as tin-plated copper-core wire; - linear output current, high precision; - small volume, light weight, easy for installation; - encapsulated with epoxy resin to ensure strong insulation ability; - ABS anti-combustion plastic casing.

  • CATV Amplifiers

    Macom Technology Solutions Holdings Inc.

    MACOM’s portfolio of single-ended and differential 75 Ω broadband amplifiers service head-end, HFC infrastructure Nodes, system and line-extender amplifies, EQAM and CPE applications. MACOM’s industry leading GaAs amplifiers are offered in a range of small, plastic leaded and leadless packages operating off standard voltage rails 5,8 & 12V. Covering reverse path, 5 – 300MHz, and forward path, 45 – 1800MHz, our amplifiers offer flat gain response, low distortion and high linearity.

  • Cable Fault Meter

    PCE Instruments

    A cable fault meter can locate open power cables, either live or dead (without current), with voltages up to 300 V. A cable fault meter can locate cables, circuits, short circuits and ground wires. To perform these functions, it is not always necessary to disconnect electrically sensitive devices or to disconnect the power from the cable which is being tested. Many cable fault meter devices can also locate ferrous and non-ferrous metals, wood and plastic with high degrees of accuracy.

  • AccuLoss®

    ALMS Systems - Measurements International Ltd.

    The measurement of electric power and energy at high voltages and currents at low power factors is becoming increasingly important economically as a way to reduce costs in an ever-growing industrial economy. Today the transformer purchaser subjects the transformer manufacturer to an economic penalty for losses that occur in load and no-load conditions. To keep these penalties as low as possible, it is important that the manufacturer accurately measure these losses. Failure to do so can result in the manufacturer losing important contract awards to their competitors who may be utilizing a more accurate system.

  • Railway and Traffic Engineering Solutions

    LXinstruments GmbH

    In the past, LXinstruments has already implemented a number of application-specific system solutions which cater for these special requirements. These solutions are often used to replace systems which have been in production for many decades. Our systems are not only employed for testing signal box technology modules, but also for testing train control system which are installed in the track bed. Due to the strong magnetic fields which occur at the DUT in combination with high voltages, the test systems require specific technical safeguards.

  • VME – NIM Power Supplies

    CAEN S.p.A.

    VME solutions are an integral part of CAEN’s design history. CAEN VME solutions for Data Acquisition and Front End applications have been part of were first developed decades ago. These solutions have been upgraded and modernized multiple times, and were recently joined by CAEN VME programmable High Voltage Boards. Thanks to the innovative GECO2020 Control Software, and the multi-master capability of CAEN VME Bridges, it is now possible to accommodate and independently control an integrated VME DAQ/HV System.

  • Inrush Current Generators for Zno Production Line

    Shanghai Guantu Technology Co., Ltd.

    Inrush Current Generator Standard: IEC61008, IEC61009, I61051/61643, ANSI C62.31, C62.33, C62.35, TU K20, K21, K44, K45, UL943Inrush Current Generator Features1. LCD screen display, built-in computer control, man-machine dialogue, easy to operate.2. Program-controlled high-voltage power supply, high voltage stability and precision3. Imported non-inductive high-power resistors are used to ensure the consistency of surge waveforms4. The main switch adopts electronic switch discharge mode, and the output polarity is automatically switched

  • HV Voltage Dividers

    ROSS ENGINEERING CORPORATION

    *DC up to 10MHz*1kV to 1,200kV DC or PK AC*To 1,875kV Impulse*To ±0.01% DC Accuracy Accredited*To ±0.2% AC Accuracy (50/60Hz) Accredited*To ±3% DC-1MHz Wideband*±3dB 5 to 30 MHz*Compact & Lightweight*For Oscilloscopes*For Recorder*For Digital Multimeters*Very Partial Discharge/Low Corona*Very Low Phase Shift*Resistive*Capacitance*Compensated Wideband*Indoor & Outdoor*Electronic and Power Class*Match Wideband Differential*High Voltage Power Quality Instrumentation

Get Help